Compatible Pulse Generators
|
|
Complementary, Open-collector
Single-pulse (A pulse), two-pulse (A, B pulse) or three-pulse (A, B, Z pulse)
H level: 8 to 12 V
L level: 2.0 V max.
|
PG Encoder Wiring Length
|
|
Complementary: 100 m (328 ft.) maximum
Open-collector: 50 m (164 ft.) maximum
|
PG Encoder Power Supply
|
|
Output voltage: 12 V ± 5%
Max. Output Current: 200 mA
|
Compatible Control Modes
|
|
V/f with PG, Closed Loop Vector, Closed Loop Vector for PM motors
|
Maximum Input Frequency
|
|
50 kHz
|
Pulse Monitor Output
|
|
Monitor for A, B, and Z pulse output: 24 V max, 30 mA
Open-collector output
|
PG Encoder Disconnect Detection
|
|
Software detection
|
Ambient Temperature
|
|
-10 °C to +50 °C (14 °F to 122 °F)
|
Humidity
|
|
95% RH or lower with no condensation
|
Storage Temperature
|
|
-20 °C to +60 °C (-4 °F to 140 °F) allowed for short-term transport of the product
|
Area of Use
|
|
Indoor (free of corrosive gas, airborne particles, etc.)
|
Altitude
|
|
1000 m (3280 ft.) or lower
|